GA series High frequency inverter data sheet | ||||
Model | GA3024MH | GA5048MH | ||
Input | Phase | L+N+PE | ||
Nominal Voltage | 208/220/230/240VAC | |||
Voltage Range | 154-264VAC±3V(Normal Mode) 185-264VAC±3V(UPS Mode) | |||
Frequency Range | 50Hz/60Hz(Adaptive) | |||
Output | Rated Power | 3000W | 5000W | |
Output Voltage(AC) | 208/220/230/240VAC±5% | |||
Output Frequency | 50/60Hz±0.1% | |||
Waveform | Pure sine wave | |||
Transfer Time( Optional) | 10ms for computer , 20ms for home appliances | |||
Peak power | 6000VA | 10000VA | ||
Overload | Battery Mode: 1min@102%~110% Load 10s@110%~130% Load 3s@130%~150% Load 200ms@>150% Load |
|||
Peak efficiency (battery mode) | >94% | >94% | ||
Battery | Rated voltage | 24Vdc | 48Vdc | |
Constant voltage charging voltage (Optional) | 28.2Vdc | 56.4Vdc | ||
Floating charge voltage (Optional) | 27Vdc | 54Vdc | ||
charger | PV charging method | MPPT | MPPT | |
PV max input power | 3500W | 5500W | ||
MPPT tracking range | 120~430Vdc | 120~430Vdc | ||
Max PV input voltage | 450Vdc | 450Vdc | ||
Max PV charging current | 60A | 80A | ||
Max AC charging current | 60A | 80A | ||
Max charging current | 60A | 80A | ||
Display | LCD display | Operating mode/load/input/output, etc. | ||
Communication port | RS232 | 5PIN/Pitch2.0mm, baud rate 2400 | ||
Expansion & configuration port | 2×5PIN/Pitch2.54mm, lithium battery BMS communication card, WIFI card, dry contact card, etc. |
|||
Parallel interface | No | Yes | ||
Environmental parameters | Operating environment temperature | 0~40℃ | ||
Operating environment humidity | 20%~95%(Non condensing) | |||
Storage temperature | -15~60℃ | |||
Altitude | The altitude should not exceed 1000m, derating above 1000m, up to 4000m, refer to IEC62040 |
|||
noise | ≤50db | |||
Certifications | EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1 |